Form preview

NFPA 80 2010-2025 free printable template

Get Form
Annual Inspection of Swinging Fire Door Assemblies Name of Facility Fire Door Assembly Location Special Locking Arrangement Number of Leafs Fire Rating of Each Leaf Fire Rating of Frame Rating of Barrier Purpose of Rated Barrier Automatic or Manual Operator Hold-open Device Inspected By Date Inspection Activity Yes No N/A Comments 1. Is the door and frame free from holes and breaks in all surfaces 2. Are all the glazing vision light frames and glazing beads intact and securely fastened 3. Are...the doors hinges frame hardware and threshold secure aligned and in working order with no visible signs of damage 4. Are there any missing or broken parts 5. Is the clearance from the door edge to the frame no more than 1/8 inch 6. Is the door undercut no more than inch 7. Does the active door leaf completely closes when operated from the full open position 8. Does the inactive leaf close before the active leaf when a coordinator is used 9. Does the latching hardware operate and secure the door...in the closed position 10. Is the door assembly free from are auxiliary hardware items which could interfere with its operation 11. Has the door been modified since it was originally installed 12. If gasketing and edge seals are installed have they been verified for integrity and operation All No answers must be fully explained* Source NFPA 80 2010 edition Supervisor s Initial Date Work Order. Is the door and frame free from holes and breaks in all surfaces 2. Are all the glazing vision light...frames and glazing beads intact and securely fastened 3. Are the doors hinges frame hardware and threshold secure aligned and in working order with no visible signs of damage 4. Are the doors hinges frame hardware and threshold secure aligned and in working order with no visible signs of damage 4. Are there any missing or broken parts 5. Is the clearance from the door edge to the frame no more than 1/8 inch 6. Are there any missing or broken parts 5. Is the clearance from the door edge to the...frame no more than 1/8 inch 6. Is the door undercut no more than inch 7. Does the active door leaf completely closes when operated from the full open position 8. Is the door undercut no more than inch 7. Does the active door leaf completely closes when operated from the full open position 8. Does the inactive leaf close before the active leaf when a coordinator is used 9. Does the latching hardware operate and secure the door in the closed position 10. Does the inactive leaf close before the...active leaf when a coordinator is used 9. Does the latching hardware operate and secure the door in the closed position 10. Is the door assembly free from are auxiliary hardware items which could interfere with its operation 11. Is the door assembly free from are auxiliary hardware items which could interfere with its operation 11. Has the door been modified since it was originally installed 12. If gasketing and edge seals are installed have they been verified for integrity and operation All No...answers must be fully explained* Source NFPA 80 2010 edition Supervisor s Initial Date Work Order.
pdfFiller is not affiliated with any government organization

Fill out, sign, and share forms from a single PDF platform

Manage all your documents quickly and securely in the cloud.
Add or replace text, adjust formatting, insert legally binding eSignatures, and send documents for signing without hopping between apps.
Add and customize fillable fields to tailor each form to your needs and ensure easy completion without printing and scanning.
Quickly share forms via email or a secure link, enabling anyone to complete forms online in seconds, on any device.
Keep all your forms and templates organized in one secure, cloud-based platform, track changes easily, and export documents in any format.
Screen
Screen
Screen
Screen

Why pdfFiller is the best tool for your documents and forms

GDPR
AICPA SOC 2
PCI
HIPAA
CCPA
FDA

End-to-end document management

From editing and signing to collaboration and tracking, pdfFiller has everything you need to get your documents done quickly and efficiently.

Accessible from anywhere

pdfFiller is fully cloud-based. This means you can edit, sign, and share documents from anywhere using your computer, smartphone, or tablet.

Secure and compliant

pdfFiller lets you securely manage documents following global laws like ESIGN, CCPA, and GDPR. It's also HIPAA and SOC 2 compliant.
Fill fillable NFPA 80 form: Try Risk Free
Rate free NFPA 80 form
4.8
satisfied
84 votes

Understanding the NFPA 80 2 Printable Form

What is the NFPA 80 2 Printable Form?

The NFPA 80 2 printable form is a crucial document used for the annual inspection of swinging fire door assemblies within facilities. It ensures that all fire safety measures are comprehensively evaluated, promoting compliance with established fire safety regulations. This form facilitates accurate inspection recording, monitoring the condition of fire door assemblies to prevent fire hazards.

Key Features of the NFPA 80 2 Printable Form

This form encompasses various important sections, including details about the facility, fire door assembly location, and various operational checks. Users can assess door and frame integrity, verify hardware functionality, and document any deficiencies or required repairs. Clear response options (Yes, No, N/A) make it easy to complete while ensuring thorough oversight of fire safety.

Best Practices for Accurate Completion

To complete the NFPA 80 2 printable form accurately, consider gathering the necessary information beforehand. Conduct a physical inspection of the door assemblies based on the checklist provided in the form, ensuring all details are recorded clearly. It is also important to have a qualified individual perform the inspection to ensure compliance and efficiency.

Who Needs the NFPA 80 2 Printable Form?

The NFPA 80 2 printable form is essential for fire safety inspectors, facility managers, and building owners responsible for maintaining fire-rated door assemblies. It is particularly relevant in environments that must adhere to strict fire safety codes, including commercial buildings, hospitals, schools, and industrial facilities.

Review and Validation Checklist

Before finalizing the NFPA 80 2 printable form, implement a review process. Check that all sections have been filled out completely and accurately, and that comments are provided for any 'No' responses. Consider having a second set of eyes review the documentation to catch potential errors.

Common Errors and Troubleshooting

Common mistakes when filling out the NFPA 80 2 printable form include incomplete sections, illegible handwriting, or misunderstanding of inspection guidelines. Regular training and clear guidelines can help reduce these errors. If issues arise, review the checklist included in the form and correct any discrepancies immediately.

Frequently Asked Questions about fire door inspection checklist form

What is the purpose of the NFPA 80 2 printable form?

The form is to document the annual inspection of swinging fire door assemblies, ensuring compliance with safety standards and regulations.

Who should perform the inspections outlined in the form?

Qualified fire safety inspectors or maintenance individuals familiar with fire safety regulations should conduct these inspections.

pdfFiller scores top ratings on review platforms

Users Most Likely To Recommend - Summer 2025
Grid Leader in Small-Business - Summer 2025
High Performer - Summer 2025
Regional Leader - Summer 2025
Great program a fairly easy to use Great program a fairly easy to use. We had to cancel because my company could not justify the expense of the program at this time.
David Norman
The best out there The best out there! I have tried using almost 10 plus similar applications but this one beats all. Really impressed about its capabilities and will surely recommend it to everyone! 100% satisfied with it!!
K.d
Easy accurate and helpful! This is an awesome tool for making even the most unprofessional professional. It is easy, concise and easily editable. It is well worth the price.
Paula Lucas
Very easy to work with.
Juan Pablo N
Love it,,its my favorite app
Susan d
great
Kate M
Show more Show less

People Also Ask about nfpa 80 fire door inspection checklist

1) Labels are clearly visible and legible. 2) No open holes or breaks exist in surfaces of either the door or frame. 4) The door, frame, hinges, hardware, and noncombustible threshold are secured, aligned, and in working order with no visible signs of damage. 5) No parts are missing or broken.
Frequently Asked Questions Check that the door is closing 'to latch' automatically: Open the door halfway and let it go – it should close to latch. Ensure that the smoke seals are in place and undamaged. Check that there are no penetrations or damage to the door. Check that the 3 hinges are secure and in good condition.
The following fire door regulations apply to buildings over 11 metres in height: Responsible Persons must check all fire doors in communal areas of the building at least every 3-months. Responsible Persons must check every flat entrance door within the building annually.
1) Labels are clearly visible and legible. 2) No open holes or breaks exist in surfaces of either the door or frame. 4) The door, frame, hinges, hardware, and noncombustible threshold are secured, aligned, and in working order with no visible signs of damage. 5) No parts are missing or broken.
Fire Doors - The 5 Step Check Check for certification. Is there a label or plug on top (or occasionally on the side) of the door to show it is a certificated fire door? Check the gaps. Check the seals. Check the hinges. Check the door closes properly.
NFPA 80 requires that fire doors be installed with a certain amount of clearance around them, such as a minimum of 1/8 inch between the door and the frame, to ensure that the door can properly seal and function in the event of a fire.
Fire rated doors are subjected to endurance testing where the specimen is exposed to extreme heat of up to 1925 degrees F for the maximum 180 minute rating. If the door remains in the frame with no through openings and limits flames, it is certified with an endurance rating of either 20/45/60/90/180 minutes.
Fire rated doors are subjected to endurance testing where the specimen is exposed to extreme heat of up to 1925 degrees F for the maximum 180 minute rating. If the door remains in the frame with no through openings and limits flames, it is certified with an endurance rating of either 20/45/60/90/180 minutes.

Related Catalogs

If you believe that this page should be taken down, please follow our DMCA take down process here .
This form may include fields for payment information. Data entered in these fields is not covered by PCI DSS compliance.