
Get the free ActiLume Classic High Bay and Low Bay Occupancy Sensors
Show details
This document provides detailed information about Philips ActiLume Classic occupancy sensors including specifications, features, installation information, applications, and ordering details.
We are not affiliated with any brand or entity on this form
Get, Create, Make and Sign actilume classic high bay

Edit your actilume classic high bay form online
Type text, complete fillable fields, insert images, highlight or blackout data for discretion, add comments, and more.

Add your legally-binding signature
Draw or type your signature, upload a signature image, or capture it with your digital camera.

Share your form instantly
Email, fax, or share your actilume classic high bay form via URL. You can also download, print, or export forms to your preferred cloud storage service.
Editing actilume classic high bay online
Here are the steps you need to follow to get started with our professional PDF editor:
1
Log in to your account. Click Start Free Trial and sign up a profile if you don't have one yet.
2
Upload a file. Select Add New on your Dashboard and upload a file from your device or import it from the cloud, online, or internal mail. Then click Edit.
3
Edit actilume classic high bay. Rearrange and rotate pages, add new and changed texts, add new objects, and use other useful tools. When you're done, click Done. You can use the Documents tab to merge, split, lock, or unlock your files.
4
Get your file. Select the name of your file in the docs list and choose your preferred exporting method. You can download it as a PDF, save it in another format, send it by email, or transfer it to the cloud.
Dealing with documents is always simple with pdfFiller.
Uncompromising security for your PDF editing and eSignature needs
Your private information is safe with pdfFiller. We employ end-to-end encryption, secure cloud storage, and advanced access control to protect your documents and maintain regulatory compliance.
How to fill out actilume classic high bay

How to fill out ActiLume Classic High Bay and Low Bay Occupancy Sensors
01
Gather all necessary tools and equipment, including the ActiLume sensor, screws, and a screwdriver.
02
Turn off the power supply to the area where the sensor will be installed for safety.
03
Select the appropriate mounting height based on the sensor's specifications.
04
Use the provided template to mark the drill holes on the ceiling where the sensor will be attached.
05
Drill holes and insert wall plugs if necessary.
06
Mount the ActiLume sensor onto the ceiling using screws, ensuring it is secure.
07
Connect the electrical wires according to the wiring diagram provided in the user manual.
08
Turn the power supply back on and test the sensor to ensure it is functioning correctly.
09
Adjust the settings and sensitivity as needed based on the specific requirements of the space.
Who needs ActiLume Classic High Bay and Low Bay Occupancy Sensors?
01
Facility managers responsible for energy-efficient lighting solutions.
02
Warehouse operators looking to optimize lighting based on occupancy.
03
Commercial buildings that require automated lighting controls.
04
Industrial facilities needing to enhance safety and reduce energy costs.
05
Retail spaces aiming to improve customer experience through effective lighting.
Fill
form
: Try Risk Free
People Also Ask about
What is the purpose of an occupancy sensor?
An occupancy sensor detects the presence of movement within its given range. The sensor detects motion and transmits the signal to the control unit. If no movement is detected after a period of time set by the user, the controller determines the space is unoccupied and switches off the light.
What is a high bay occupancy sensor?
The HBP Series High Bay Passive Infrared (PIR) Occupancy Sensors provide automatic control of individual LED and fluorescent lighting fixtures in warehouses and other indoor high and low bay spaces.
What is a high bay sensor?
The High Bay Sensor is a motion sensor ideal for industrial lighting applications, such as production halls. It can be used with the Wattstopper PLUS Light Management System using a DALI High Bay Coupler. Daylight sensing can also be achieved by using the DALI High Bay Coupler.
Where are occupancy sensors located?
Occupancy sensors shall be installed in all classrooms, conference/meeting rooms, employee lunch and break rooms, private offices, restrooms, storage rooms and janitorial closets, and other spaces 300 square feet (28 m2) or less enclosed by floor-to-ceiling height partitions.
What are the two common types of occupancy sensors?
Comparison of Key Occupancy Sensing Technologies TechnologyCommon Applications PIR (Passive Infrared) Offices, Workstations Restrooms, Libraries Ultrasonic Occupancy Sensors Restrooms, Libraries, Hospital Patient Rooms Microwave Occupancy Sensors Parking Lots and Garages, Warehouses, Outdoor Security3 more rows
What is a high bay light?
High bay lights are used to light up spaces whose ceilings are higher than 20ft from the floor and around 40ft. Also, for these lights to operate efficiently from this height, they need specially engineered reflectors in the case of HPS / MH bulbs and lens angles in the case of LED high bays.
For pdfFiller’s FAQs
Below is a list of the most common customer questions. If you can’t find an answer to your question, please don’t hesitate to reach out to us.
What is ActiLume Classic High Bay and Low Bay Occupancy Sensors?
ActiLume Classic High Bay and Low Bay Occupancy Sensors are devices designed to detect the presence of people in high or low bay areas and control lighting accordingly to enhance energy efficiency in commercial and industrial settings.
Who is required to file ActiLume Classic High Bay and Low Bay Occupancy Sensors?
Individuals or organizations responsible for the installation and operation of ActiLume Classic High Bay and Low Bay Occupancy Sensors in applicable facilities are typically required to file related documentation.
How to fill out ActiLume Classic High Bay and Low Bay Occupancy Sensors?
To fill out documentation for ActiLume Classic High Bay and Low Bay Occupancy Sensors, one should provide specific details such as the location of installation, type of sensor used, operational parameters, and usage data.
What is the purpose of ActiLume Classic High Bay and Low Bay Occupancy Sensors?
The purpose of ActiLume Classic High Bay and Low Bay Occupancy Sensors is to optimize energy consumption by automatically switching lights on or off based on occupancy, thereby improving energy efficiency and reducing operational costs.
What information must be reported on ActiLume Classic High Bay and Low Bay Occupancy Sensors?
The information that must be reported includes sensor model, installation date, operational settings, energy savings achieved, and any maintenance performed on the sensors.
Fill out your actilume classic high bay online with pdfFiller!
pdfFiller is an end-to-end solution for managing, creating, and editing documents and forms in the cloud. Save time and hassle by preparing your tax forms online.

Actilume Classic High Bay is not the form you're looking for?Search for another form here.
Relevant keywords
Related Forms
If you believe that this page should be taken down, please follow our DMCA take down process
here
.
This form may include fields for payment information. Data entered in these fields is not covered by PCI DSS compliance.